HOW TO CALCULATE PILE LOAD CAPACITY IN COHESIONLESS SOIL USING SPT OR N-VALUES?

Pile load capacity calculation using standard penetration resistance

Pile Load Capacity Calculation Using Standard Penetration Resistance This method of calculating pile load capacity in cohesion less soil (i.e. in sand) was suggested by Meyerhof. Meyerhof suggested the following equation, to calculate the ultimate pile load capacity in saturated sand, using standard penetration resistance (N). In the formula given below the 1st term gives … Read more

HOW TO CALCULATE BEARING CAPACITY OF SHALLOW FOUNDATION IN SAND FROM SPT VALUES OR N-VALUES (IS-6403)

Step-by-Step Procedure for Calculation of Bearing Capacity from Standard Penetration Test Values or N-values Step-1 Perform standard penetration test on the location for which you want to calculate bearing capacity. This is done as per standard procedure given in IS-2131. Standard penetration test must be done at every 75 cm in vertical direction. Step-2 Decide … Read more

WHAT IS NON-DESTRUCTIVE TESTING OF CONCRETE & VARIOUS NDT TEST METHODS?

NDT test on concrete

Non-Destructive Testing of Concrete (NDT on Concrete) Non destructive test is a method of testing existing concrete structures to assess the strength and durability of concrete structure. In the non destructive method of testing, without loading the specimen to failure (i.e. without destructing the concrete) we can measure strength of concrete. Now days this method … Read more

WHAT CAUSES CRACKS IN CONCRETE AND HOW TO PREVENT IT?

causes of cracks in concrete and its remedies

Causes of Cracks in Concrete and its Remedies Cracks in concrete are caused due to following factors. One of the main causes of cracks in concrete is the cooling and contraction due to setting of concrete. Volume change and stresses due to shrinkage are independent of any external load or stress applied. Cracks may develop … Read more

WHAT IS CARBONATION OF CONCRETE?

What is carbonation of concrete

Carbonation of Concrete Carbonation of concrete is one of the reasons for corrosion of reinforcement. It is a process by which carbon dioxide from air penetrates into the concrete and reacts with calcium hydroxide to form calcium carbonates. The percentage of CO2 present is air vary from place to place. In case of rural areas … Read more

HOW TO DECIDE MAXIMUM SIZE OF COARSE AGGREGATE TO BE USED IN CONCRETE?

how to decide maximum size of aggregate to be

For the same strength or workability, concrete with large size aggregate will require lesser quantity of cement than concrete with a smaller size aggregate. In a mass concrete work the use of larger size aggregate will be useful due to the lesser consumption of cement. This will also reduce the heat of hydration and the … Read more

WHAT IS THE PRINCIPLE BEHIND PRESTRESSED CONCRETE?

Prestressed concrete principle and application

Prestressed Concrete Prestressed concrete is a modified form of reinforced concrete. it not only eliminates the weakness of concrete, but also makes it possible to take full advantage of compressive strength of concrete. The term “Prestressed Concrete” is applied to those reinforced concrete members in which concrete is subjected to compressive stresses, before the external … Read more

WHAT TO CONSIDER WHILE USING PPC, BFSC OR MINERAL ADMIXTURE IN CONCRETE?

point to consider while using mineral admixture in concrete

Points to Consider Mixing of mineral admixtures with OPC at site should not normally be permitted. However for projects requiring use of blended cement from durability and strength considerations, which is not available from the cement manufacturer blending may be permitted through a specific facility created at site with complete automated process control to achieve … Read more

HOW TO PERFORM PLATE LOAD TEST OF SOIL ON SITE?

Fig-1 (Plate Load Test Setup)

Objective To perform plate load test to obtain a load-settlement curve of a soil at a particular depth so as to estimate the ultimate bearing capacity a foundation. Apparatus Test plate of square size (300 mm or 450 mm or 600 mm or 750 mm) Hydraulic jack (50 T capacity) Hydraulic pump (50 T capacity) … Read more